Main Article Content
Abstract
Objectives: To determine the half-life of haemofilters in critically ill patients admitted to the ICU and the main factors associated with their duration.
Methodology: Cross-sectional observational descriptive study conducted in a polyvalent adult intensive care unit. The haemofilters placed in 67 patients over 18 years of age between January and November 2019 were studied. Variables: age, sex, weight, admission unit, blood flow velocity, filtration fraction, hourly debit, system anticoagulation, activated thromboplastin time (APTT), medical indication for therapy, cause of withdrawal, catheter location, start and end time of therapy.
Results: The mean age of the patients was 62.66 years (±9.95), 81 (71.64%) men. A total of 238 haemofilters with a mean lifetime of 26.28 hours (±22.8) were analysed. Femoral catheters accounted for 80.1 %, jugular catheters for 19 % and subclavian catheters for 0.8 %. Sodium heparin was used as anticoagulation therapy in 45.8 %, citrates in 20.2 % and no anticoagulation in 34 %. Mean blood flow velocity was 190.08 ml/min (±53.48). A statistical relationship was found between the variables blood flow (rs=0.208; p=0.001), catheter location and haemofilter duration (p=0.03).
Conclusions: The half-life of the haemofilter was 26 hours. Blood flow velocity and catheter location are factors that affect the duration of the haemofilter
Keywords
Article Details
Author copyright notice
© Authors grant the publisher the non-exclusive licence to publish the work and consent to its use and distribution under the Creative Commons Attribution - NonCommercial 4.0 International (CC BY-NC 4.0) licence. Read the licensing information and the legal text here. This must be expressly stated wherever necessary.
References
- Bagshaw SM, George C, Bellomo R, ANZICS Database Management Committe. A comparison of the RIFLE and AKIN criteria for acute kidney injury in critically ill patients. Nephrol Dial Transplant Off Publ Eur Dial Transpl Assoc - Eur Ren Assoc. 2008 May;23(5):1569-74. DOI: https://doi.org/10.1093/ndt/gfn009
- Úbeda-Iglesias A, Herrera-Rojas D, Gómez-González C. Encuesta sobre el manejo del fracaso renal agudo y las técnicas de reemplazo renal en las unidades de cuidados intensivos españolas. Med Intensiva. 2015;39(2):84-9. DOI: https://doi.org/10.1016/j.medin.2014.04.001
- Herrera Gutiérrez ME. Técnicas de reemplazo renal continuas frente a las intermitentes: pro-continuas. Medicina Intensiva. 2009;33(2):88-92. DOI: https://doi.org/10.1016/S0210-5691(09)70687-4
- Rodríguez Segura MD, Moreno Vicente M, Pérez Rodríguez N. Técnicas continuas de depuración extrarrenal en el paciente crítico. Enferm Integral. 2015;108:39-41.
- Gutiérrez Rodríguez P. Técnicas continuas de depuración renal extracorpórea en el paciente crítico: fundamentos y componentes del sistema de terapia. Tiempos de enfermería y salud. 2020;2(9):14-9.
- Romero-García M, de la Cueva-Ariza L, Delgado-Hito P. Actualización en técnicas continuas de reemplazo renal. Enferm Intensiva. 2013 Jul;24(3):113-9. DOI: https://doi.org/10.1016/j.enfi.2013.01.004
- García Olert A, Hernández Sánchez AI, Miralles Andujar FJ, Cortés Carmona J, Domínguez Bernal MÁ, Caro Nieto ME. Experiencia en las técnicas continuas de reemplazo renal en cuidados intensivos: Determinantes de la duración del hemofiltro. Rev Soc Esp Enferm Nefrológica. 2008;11:259-64. DOI: https://doi.org/10.4321/S1139-13752008000400003
- Guirao Moya A, Esteban Sánchez M, Fernández Gaute N, Murga González A., Vergara Diez L., Martínez García M.P., et al. Monitorización de presiones en técnicas continuas de depuración extrarrenal. Enferm Intensiva. 2010;21(1):28-33. DOI: https://doi.org/10.1016/j.enfi.2009.11.001
- Maynar Moliner J, Honore PM, Sánchez-Izquierdo Riera JA, Herrera Gutiérrez M, Spapen HD. Handling continuous renal replacement therapy-related adverse effects in intensive care unit patients: the dialytrauma concept. Blood Purif. 2012;34(2):177-85. DOI: https://doi.org/10.1159/000342064
- Molano Álvarez E, Guirao Moya A, Esteban Sánchez ME, Sanz Cruz P, García Delgado E, Sánchez-Izquierdo Riera JÁ. Detección de riesgos para la seguridad del paciente en la implementación de técnicas continuas de depuración extracorpórea. Enferm Intensiva. 2011;22(1):39-45. DOI: https://doi.org/10.1016/j.enfi.2010.09.006
- Molano Álvarez E, Cornejo Bauer C, García Hernández R, Rojo Cabello S, Cuenca Solanas M, García Fuentes C. Enfermería de cuidados críticos y técnicas continuas de reemplazo renal en la Comunidad de Madrid. Enferm Intensiva. 2003;14(4):135-47. DOI: https://doi.org/10.1016/S1130-2399(03)78119-X
- Sanz M, Hidalgo F, García-Fernández N. Supervivencia de circuitos de técnicas de depuración extrarrenal continua en pacientes críticos con o sin anticoagulación convencional: estudio observacional prospectivo. An Sist Sanit Navar. 2017;40(1):77-84. DOI: https://doi.org/10.23938/ASSN.0008
- Gaínza FJ, Sánchez-Izquierdo JA, Poch E, Maduell F, Solozábal C, Otero A, et al. Guías SEN - Actuación en el fracaso renal agudo. Tratamiento sustitutivo de la función renal. Nefrol 2007; 27(Supl 3):109-91.
- Shoemaker W, Ayes S, Grenvik A, Holbrook P. Shoemaker W, Ayes S, Grenvik A, Holbrook P. Tratado de Medicina Crítica y Terapia Intensiva. Médica Panamericana. Madrid: Médica Panamericana; 4.a ed; 2002 .p. 1673.
- Vinagre Gaspar R, Cornejo Bauer C, Murillo Pérez A, Molano Alvarez E, Muñoz López O, Morales Sánchez C, et al. Pérdidas sanguíneas diagnósticas en pacientes con trauma grave. Enferm Intensiva. 2010 Sep;21(3):120-5. DOI: https://doi.org/10.1016/j.enfi.2010.04.001
- Houllé-Veyssière M, Courtin A, Zeroual N, Gaudard P, Colson PH. Continuous venovenous renal replacement therapy in critically ill patients: A work load analysis. Intensive Crit Care Nurs. 2016t;36:35-41. DOI: https://doi.org/10.1016/j.iccn.2016.04.001
- Reyes-Marín FA. Hemodiálisis y terapias continuas. Gac Méd Méx. 2008;144(6):517-19.
- Herrera Gutiérrez ME, Daga Ruiz D, Seller Pérez G, García Alcántara A, De la Rubia de Gracia C, Ruiz del Fresno L. Uso de las técnicas continuas de reemplazo renal en las Unidades de Cuidados Intensivos en España. Una encuesta a nivel nacional. Med Intensiva. 2000;24(8):341-7. DOI: https://doi.org/10.1016/S0210-5691(00)79620-3
- Navas A, Ferrer R, Martínez M, Martínez ML, Haro C de, Artigas A. Terapia de reemplazo renal en paciente crítico: cambios evolutivos del tratamiento en los últimos años. Med Intensiva. 2012;36(8):540-7. DOI: https://doi.org/10.1016/j.medin.2012.01.005
- Tomasa Irriguible TM, Sabater Riera J, Poch Lopez de Briñas L de, Fort Ros J, LLoret Cora MJ, Roc Antònio J, et al. Manejo actual de las terapias continuas de reemplazo renal: Estudio epidemiológico multicéntrico. Med Intensiva. 2017;41(4):216-26. DOI: https://doi.org/10.1016/j.medin.2016.07.002
- Fealy N, Aitken L, Toit E du, Baldwin I. Continuous renal replacement therapy: current practice in Australian and New Zealand intensive care units. Crit Care Resusc J Australas Acad Crit Care Med. 2015 Jun;17(2):83-91.
- Echevarria-Uraga JJ, García-Garai N, Muñoz-González RI. Accesos venosos para hemodiálisis: abordaje yugular. Diálisis Traspl. 2014;35(4):163-8. DOI: https://doi.org/10.1016/j.dialis.2014.11.003
- Cobo Sánchez JL, Menezo Viadero R, Gándara Revuelta M, Pelayo Alonso R, Villa Llamazares C, Maza Sota MA et al. ¿Influye tanto el flujo de sangre en la eficacia dialítica?. Comunicaciones presentadas al XXXI Congreso Nacional de la Sociedad Española de Enfermería Nefrológica. 2008. p. 389-94.
- Gallego Cobos N. y Dorao Martínez-Romillo R. Fracaso renal agudo en el paciente pediátrico. Nefrología. 2007; 27(s3):S257-74.
- Kee YK, Kim EJ, Park KS, Han SG, Han IM, Yoon CY, et al. The effect of specialized continuous renal replacement therapy team in acute kidney injury patients treatment. Yonsei Med J. 2015 May;56(3):658-65. DOI: https://doi.org/10.3349/ymj.2015.56.3.658
- Juncos LA, Chandrashekar K, Karakala N, Baldwin I. Vascular access, membranes and circuit for CRRT. Semin Dial. 2021;00:1-10. DOI: https://doi.org/10.1111/sdi.12977
- Oh HJ, Lee MJ, Kim CH, Kim DY, Lee HS, Park JT, et al. The benefit of specialized team approaches in patients with acute kidney injury undergoing continuous renal replacement therapy: propensity score matched analysis. Crit Care. 2014 Ago;18(4):454. DOI: https://doi.org/10.1186/s13054-014-0454-8
- Carneiro P, Santiago MJ, López J, Castillo A, López-Herce J. Anticoagulación regional con citrato en las técnicas de depuración extrarrenal continuas. An Pediatr Barc Spain 2003. 2012 Ene;76(1):49-50. DOI: https://doi.org/10.1016/j.anpedi.2011.07.028
- Mottes T, Owens T, Niedner M, Juno J, Shanley TP, Heung M. Improving delivery of continuous renal replacement therapy: impact of a simulation-based educational intervention. Pediatr Crit Care Med J Soc Crit Care Med World Fed Pediatr Intensive Crit Care Soc. 2013 Oct;14(8):747-54. DOI: https://doi.org/10.1097/PCC.0b013e318297626e
- Bouman CSC, de Pont A-CJM, Meijers JCM, Bakhtiari K, Roem D, Zeerleder S, et al. The effects of continuous venovenous hemofiltration on coagulation activation. Crit Care Lond Engl. 2006;10(5):R150. DOI: https://doi.org/10.1186/cc5080
- Valdenebro M, Martín-Rodríguez L, Tarragón B, Sánchez-Briales P, Portolés J. Terapia de reemplazo renal en pacientes críticamente enfermos con lesión renal aguda: perspectiva del nefrólogo 2020. Nefrologia. 2021;41(2):102-14. DOI: https://doi.org/10.1016/j.nefro.2020.07.016
- Brain M, Winson E, Roodenburg O, McNeil J. Non anti-coagulant factors associated with filter life in continuous renal replacement therapy (CRRT): a systematic review and meta-analysis. BMC Nephrol. 2017 Feb;18(1):69. DOI: https://doi.org/10.1186/s12882-017-0445-5
- Kim IB, Fealy N, Baldwin I, Bellomo R. Premature circuit clotting due to likely mechanical failure during continuous renal replacement therapy. Blood Purif. 2010;30(2):79-83. DOI: https://doi.org/10.1159/000319001
- Berrocal FJ, Maqueda M, De Dios A, Moreno C, Jimenez J. Percepción de los conocimientos adquiridos en técnicas continuas de depuración extracorpórea en profesionales de cuidados intensivos. Tesela [Internet]. 2020 [consultado 04 Mar 2021];27(e12657). Disponible en: http://ciberindex.com/index.php/ts/article/view/e12657.
- Tobo Medina N. Evaluación de una intervención de Enfermería para prevenir la coagulación del circuito extracorpóreo en hemodiálisis. Enferm Glob. 2015;14:276-85. DOI: https://doi.org/10.6018/eglobal.14.4.207261
- Arenas Jiménez MD, Ferre G, Álvarez-Ude F. Estrategias para aumentar la seguridad del paciente en hemodiálisis: Aplicación del sistema de análisis modal de fallos y efectos (sistema AMFE). Nefrol Madr. 2017;37:608-21. DOI: https://doi.org/10.1016/j.nefro.2017.04.007
References
Bagshaw SM, George C, Bellomo R, ANZICS Database Management Committe. A comparison of the RIFLE and AKIN criteria for acute kidney injury in critically ill patients. Nephrol Dial Transplant Off Publ Eur Dial Transpl Assoc - Eur Ren Assoc. 2008 May;23(5):1569-74. DOI: https://doi.org/10.1093/ndt/gfn009
Úbeda-Iglesias A, Herrera-Rojas D, Gómez-González C. Encuesta sobre el manejo del fracaso renal agudo y las técnicas de reemplazo renal en las unidades de cuidados intensivos españolas. Med Intensiva. 2015;39(2):84-9. DOI: https://doi.org/10.1016/j.medin.2014.04.001
Herrera Gutiérrez ME. Técnicas de reemplazo renal continuas frente a las intermitentes: pro-continuas. Medicina Intensiva. 2009;33(2):88-92. DOI: https://doi.org/10.1016/S0210-5691(09)70687-4
Rodríguez Segura MD, Moreno Vicente M, Pérez Rodríguez N. Técnicas continuas de depuración extrarrenal en el paciente crítico. Enferm Integral. 2015;108:39-41.
Gutiérrez Rodríguez P. Técnicas continuas de depuración renal extracorpórea en el paciente crítico: fundamentos y componentes del sistema de terapia. Tiempos de enfermería y salud. 2020;2(9):14-9.
Romero-García M, de la Cueva-Ariza L, Delgado-Hito P. Actualización en técnicas continuas de reemplazo renal. Enferm Intensiva. 2013 Jul;24(3):113-9. DOI: https://doi.org/10.1016/j.enfi.2013.01.004
García Olert A, Hernández Sánchez AI, Miralles Andujar FJ, Cortés Carmona J, Domínguez Bernal MÁ, Caro Nieto ME. Experiencia en las técnicas continuas de reemplazo renal en cuidados intensivos: Determinantes de la duración del hemofiltro. Rev Soc Esp Enferm Nefrológica. 2008;11:259-64. DOI: https://doi.org/10.4321/S1139-13752008000400003
Guirao Moya A, Esteban Sánchez M, Fernández Gaute N, Murga González A., Vergara Diez L., Martínez García M.P., et al. Monitorización de presiones en técnicas continuas de depuración extrarrenal. Enferm Intensiva. 2010;21(1):28-33. DOI: https://doi.org/10.1016/j.enfi.2009.11.001
Maynar Moliner J, Honore PM, Sánchez-Izquierdo Riera JA, Herrera Gutiérrez M, Spapen HD. Handling continuous renal replacement therapy-related adverse effects in intensive care unit patients: the dialytrauma concept. Blood Purif. 2012;34(2):177-85. DOI: https://doi.org/10.1159/000342064
Molano Álvarez E, Guirao Moya A, Esteban Sánchez ME, Sanz Cruz P, García Delgado E, Sánchez-Izquierdo Riera JÁ. Detección de riesgos para la seguridad del paciente en la implementación de técnicas continuas de depuración extracorpórea. Enferm Intensiva. 2011;22(1):39-45. DOI: https://doi.org/10.1016/j.enfi.2010.09.006
Molano Álvarez E, Cornejo Bauer C, García Hernández R, Rojo Cabello S, Cuenca Solanas M, García Fuentes C. Enfermería de cuidados críticos y técnicas continuas de reemplazo renal en la Comunidad de Madrid. Enferm Intensiva. 2003;14(4):135-47. DOI: https://doi.org/10.1016/S1130-2399(03)78119-X
Sanz M, Hidalgo F, García-Fernández N. Supervivencia de circuitos de técnicas de depuración extrarrenal continua en pacientes críticos con o sin anticoagulación convencional: estudio observacional prospectivo. An Sist Sanit Navar. 2017;40(1):77-84. DOI: https://doi.org/10.23938/ASSN.0008
Gaínza FJ, Sánchez-Izquierdo JA, Poch E, Maduell F, Solozábal C, Otero A, et al. Guías SEN - Actuación en el fracaso renal agudo. Tratamiento sustitutivo de la función renal. Nefrol 2007; 27(Supl 3):109-91.
Shoemaker W, Ayes S, Grenvik A, Holbrook P. Shoemaker W, Ayes S, Grenvik A, Holbrook P. Tratado de Medicina Crítica y Terapia Intensiva. Médica Panamericana. Madrid: Médica Panamericana; 4.a ed; 2002 .p. 1673.
Vinagre Gaspar R, Cornejo Bauer C, Murillo Pérez A, Molano Alvarez E, Muñoz López O, Morales Sánchez C, et al. Pérdidas sanguíneas diagnósticas en pacientes con trauma grave. Enferm Intensiva. 2010 Sep;21(3):120-5. DOI: https://doi.org/10.1016/j.enfi.2010.04.001
Houllé-Veyssière M, Courtin A, Zeroual N, Gaudard P, Colson PH. Continuous venovenous renal replacement therapy in critically ill patients: A work load analysis. Intensive Crit Care Nurs. 2016t;36:35-41. DOI: https://doi.org/10.1016/j.iccn.2016.04.001
Reyes-Marín FA. Hemodiálisis y terapias continuas. Gac Méd Méx. 2008;144(6):517-19.
Herrera Gutiérrez ME, Daga Ruiz D, Seller Pérez G, García Alcántara A, De la Rubia de Gracia C, Ruiz del Fresno L. Uso de las técnicas continuas de reemplazo renal en las Unidades de Cuidados Intensivos en España. Una encuesta a nivel nacional. Med Intensiva. 2000;24(8):341-7. DOI: https://doi.org/10.1016/S0210-5691(00)79620-3
Navas A, Ferrer R, Martínez M, Martínez ML, Haro C de, Artigas A. Terapia de reemplazo renal en paciente crítico: cambios evolutivos del tratamiento en los últimos años. Med Intensiva. 2012;36(8):540-7. DOI: https://doi.org/10.1016/j.medin.2012.01.005
Tomasa Irriguible TM, Sabater Riera J, Poch Lopez de Briñas L de, Fort Ros J, LLoret Cora MJ, Roc Antònio J, et al. Manejo actual de las terapias continuas de reemplazo renal: Estudio epidemiológico multicéntrico. Med Intensiva. 2017;41(4):216-26. DOI: https://doi.org/10.1016/j.medin.2016.07.002
Fealy N, Aitken L, Toit E du, Baldwin I. Continuous renal replacement therapy: current practice in Australian and New Zealand intensive care units. Crit Care Resusc J Australas Acad Crit Care Med. 2015 Jun;17(2):83-91.
Echevarria-Uraga JJ, García-Garai N, Muñoz-González RI. Accesos venosos para hemodiálisis: abordaje yugular. Diálisis Traspl. 2014;35(4):163-8. DOI: https://doi.org/10.1016/j.dialis.2014.11.003
Cobo Sánchez JL, Menezo Viadero R, Gándara Revuelta M, Pelayo Alonso R, Villa Llamazares C, Maza Sota MA et al. ¿Influye tanto el flujo de sangre en la eficacia dialítica?. Comunicaciones presentadas al XXXI Congreso Nacional de la Sociedad Española de Enfermería Nefrológica. 2008. p. 389-94.
Gallego Cobos N. y Dorao Martínez-Romillo R. Fracaso renal agudo en el paciente pediátrico. Nefrología. 2007; 27(s3):S257-74.
Kee YK, Kim EJ, Park KS, Han SG, Han IM, Yoon CY, et al. The effect of specialized continuous renal replacement therapy team in acute kidney injury patients treatment. Yonsei Med J. 2015 May;56(3):658-65. DOI: https://doi.org/10.3349/ymj.2015.56.3.658
Juncos LA, Chandrashekar K, Karakala N, Baldwin I. Vascular access, membranes and circuit for CRRT. Semin Dial. 2021;00:1-10. DOI: https://doi.org/10.1111/sdi.12977
Oh HJ, Lee MJ, Kim CH, Kim DY, Lee HS, Park JT, et al. The benefit of specialized team approaches in patients with acute kidney injury undergoing continuous renal replacement therapy: propensity score matched analysis. Crit Care. 2014 Ago;18(4):454. DOI: https://doi.org/10.1186/s13054-014-0454-8
Carneiro P, Santiago MJ, López J, Castillo A, López-Herce J. Anticoagulación regional con citrato en las técnicas de depuración extrarrenal continuas. An Pediatr Barc Spain 2003. 2012 Ene;76(1):49-50. DOI: https://doi.org/10.1016/j.anpedi.2011.07.028
Mottes T, Owens T, Niedner M, Juno J, Shanley TP, Heung M. Improving delivery of continuous renal replacement therapy: impact of a simulation-based educational intervention. Pediatr Crit Care Med J Soc Crit Care Med World Fed Pediatr Intensive Crit Care Soc. 2013 Oct;14(8):747-54. DOI: https://doi.org/10.1097/PCC.0b013e318297626e
Bouman CSC, de Pont A-CJM, Meijers JCM, Bakhtiari K, Roem D, Zeerleder S, et al. The effects of continuous venovenous hemofiltration on coagulation activation. Crit Care Lond Engl. 2006;10(5):R150. DOI: https://doi.org/10.1186/cc5080
Valdenebro M, Martín-Rodríguez L, Tarragón B, Sánchez-Briales P, Portolés J. Terapia de reemplazo renal en pacientes críticamente enfermos con lesión renal aguda: perspectiva del nefrólogo 2020. Nefrologia. 2021;41(2):102-14. DOI: https://doi.org/10.1016/j.nefro.2020.07.016
Brain M, Winson E, Roodenburg O, McNeil J. Non anti-coagulant factors associated with filter life in continuous renal replacement therapy (CRRT): a systematic review and meta-analysis. BMC Nephrol. 2017 Feb;18(1):69. DOI: https://doi.org/10.1186/s12882-017-0445-5
Kim IB, Fealy N, Baldwin I, Bellomo R. Premature circuit clotting due to likely mechanical failure during continuous renal replacement therapy. Blood Purif. 2010;30(2):79-83. DOI: https://doi.org/10.1159/000319001
Berrocal FJ, Maqueda M, De Dios A, Moreno C, Jimenez J. Percepción de los conocimientos adquiridos en técnicas continuas de depuración extracorpórea en profesionales de cuidados intensivos. Tesela [Internet]. 2020 [consultado 04 Mar 2021];27(e12657). Disponible en: http://ciberindex.com/index.php/ts/article/view/e12657.
Tobo Medina N. Evaluación de una intervención de Enfermería para prevenir la coagulación del circuito extracorpóreo en hemodiálisis. Enferm Glob. 2015;14:276-85. DOI: https://doi.org/10.6018/eglobal.14.4.207261
Arenas Jiménez MD, Ferre G, Álvarez-Ude F. Estrategias para aumentar la seguridad del paciente en hemodiálisis: Aplicación del sistema de análisis modal de fallos y efectos (sistema AMFE). Nefrol Madr. 2017;37:608-21. DOI: https://doi.org/10.1016/j.nefro.2017.04.007